top of page

Eddy Current Technology

images (4).jpg
Eddy_Current_1.jpg
download (1).jpg
download (3).jpg
download (5).jpg

Induce high frequency electromagnetic field. Eddy Currents will
flow in the test piece. Uniform field is modified as defects pass.

 

  • Can be used in any electrical conductive material.

  • Best for small OD, thin wall tubes. (2”OD and less, 3/16” wall max)

  • Good for high mill speeds, test at higher temperatures

  • Disadvantages include sensitivity to material geometry & property is not related to defects and poor depth penetration.

  • Ferromagnetic materials require magnetic saturators.

 

​

System information

  • In ferromagnetic material, the material must be magnetically saturated to allow for

  • penetration of the Eddy Currents into the material

  • Parameters to set up = Current, Frequency, Gain and Rotation

  • On-Line or Off-Line systems available (On-Line: prior to cutting, Off-Line: after cutting)

  • Weld Line or Full Body Inspection systems available

  • Minimum OD = 0.500” (12,7mm) to Maximum OD 6.500”

  • Maximum recommended wall thickness = 0.188” (4,8mm)

  • Maximum tested Speed 300ft/min (91m/min)

  • Calibrated with 1/13” and 1/8” drilled holes

  • Recommended for inspection of thin wall material only

Download doc

Amtek International LLC

12161 Ken Adams Way

Suite 110W

Wellington, FL 33414   USA

​

Tel: (561)-421-4394

© 2020 Amtekint.com